Proudly Serving Northeastern Georgia, Clarke, Gwinnett, Hall Counties and nearby
A Realtor in Lawrenceville, GA, contacted Georgia Radon Defense for a quote for their seller, who was negotiating the sale of a home with elevated radon. The buyer's home inspector did a radon test, and the average was 4.3 pCi/L.
We did a site visit to come up with a mitigation plan. During the visit, Mike discovered that the garage slab was supported by the foundation wall, making it a contributor to the radon gas measured in the basement. He added a second tap to address this adjacent foundation to ensure a "passing" result and achieve the lowest possible post-mitigation radon levels for the new homeowner.