Videos

Radon Mitigation Inspection - Radon System Inspection in Dacula, GA

A concerned homeowner in Dacula, GA, called Georgia Radon Defense to get a free estimate for a radon mitigation system. While inspecting the property for the system design, we discovered that he already had an active radon mitigation system. Unfortunately, the system was not performing. The only way to judge a radon system is by doing a radon test. He had several consumer-grade monitors, and the radon average was creeping up as the seasons changed with cooler weather creeping in.

 

Upon further evaluation, we determined that the weight of the system exhaust piping had pushed down the radon fan and caused a water trap in the piping. There were several other issues with the system, but we decided to focus on eliminating the water trap and leveling the fan to see if that was the cause of the poor performance. 

 